> AT+USOCR=17
+USOCR: 0
OK
/*IP address of udp.os.1nce.com for this example is 10.60.8.90 */
> AT+USOST=0,"10.60.8.90",4445,18,"Hello from 1NCE OS"
+USOST: 0,18
OK
> AT+USOCL=0
OK
Preparation
Configure the SARA-R410M module with the appropriate network settings, such as the APN and operator ID, and ensure that it is connected to the cellular network.
create a new socket for communication
The module will respond with the socket identifier (socket ID) if the command is successful.
Send the message to 1NCEOS
This command would send the string "Hello from 1NCE OS" over socket ID 0 to the remote server with the IP address "10.60.8.90" on port 4445. response indicates that the "AT+USOST" command was successful, and it provides the socket ID and the number of bytes sent.
Close the Socket
This command would close the socket connection with socket ID 0. After sending the command, the module should respond with an "OK" response indicating that the socket was successfully closed.